EasyManua.ls Logo

HiDew DOS - 2.5 Functions

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation, use and maintenance manual rev08
DDS-DCS-DVS-DOS - Dehumidifiers for small swimming pools
13 - 60
2.5 FUNCTIONS
The DDS, DCS, DVS and DOS units are equipped with a powerful control with graphic display and
on-board temperature and humidity probes that make the dehumidifier completely autonomous
in reading and managing temperature and humidity.
The control consists of a card with programmable microprocessor and a graphic display that
allows a large number of functions and options that can be easily managed thanks to a simple,
complete and intuitive interface.
The dehumidifier management software is entirely developed in the company by highly specialist
technicians. The Control display can be remoted up to 20m away and, thanks to the temperature and humidity probe on the
machine, it can manage temperature, humidity and machine stand-by time bands.
Personalised software is available on request in special version.
Below are all the control functions:
- Display of unit operating status and/or alarms
- Temperature and humidity probe on the machine
- Low evaporation pressure protection probe
- Management of 3 ventilation speeds in dehumidification, recirculation and heating
- Stand-by time band management
- Time slot temperature management
- Time slot humidity management
- Alarm history management
- Simultaneous management of electric heating elements and hot water coil with 3-way valve (models 040 - 050 - 060
excluded)
- Automatic static defrost management
- Automatic hot gas defrost management
- Digital output for generic alarm
- Backlit graphic display
- Possibility to remote the display for a wall positioning
2.6 OPTIONS
DDS
DCS
DVS
DOS
Hot water coil with 3-way valve
Electric heating elements
EC modulating electronic fan
SERIES
SERIES
Hot gas defrost
Silenced version with soundproofing of the compressor
Display remote kit (10 or 20 m)
-
-
RS485 Modbus serial card
Support feet kit for floor installation
-
-
-
Wall crossing plenum kit (2 pcs)
-
-
-
Air supply and return plenum (2 pcs)
-
-
-
Supply and return air grilles (2 pcs)
-
-
-
Display mounted on board
-
-
-
Upwards supply rectangular flange kit
-
-
-
Rear supply rectangular flange kit
-
-
-
Display remoting cable (5, 10 or 20 m)
-
-
Remote display with connection cable (2 m)
-
-
SERIES
SERIES
High efficiency filter
-
-
-
Circular channel supply flange kit
-
-
-
Circular channel return flange kit
-
-
-
= option available

Related product manuals