30: Bar Code Mode: No ng connected
This fault is shown if the output lead is not connected to a ng when a bar code is read. Con-
nect the ng.
31: Bar Code Mode: Ohms error
This fault is shown if the connected ng resistance is dierent from that coded into the bar
code. Try another ng.
40: Bar Code Invalid: Temperature Compensaon.
Digits 22 and 23 of the bar code have been decoded incorrectly.
41: Bar Code Invalid: Resistance Coecient.
Digit 18 of the bar code has been decoded incorrectly.
42: Bar Code Invalid: Welding Voltage.
Digits 13 and 14 of the bar code have been decoded incorrectly.
43: Bar Code Invalid: Regulaon Mode.
Digit 12 of the bar code has been decoded incorrectly.
44: Bar Code Invalid: Fing Size.
Digits 9, 10 and 11 of the bar code have been decoded incorrectly.
45: Bar Code Invalid: Cooling Time.
Digit 7 of the bar code has been decoded incorrectly.
46: Bar Code Invalid: Fusion Cycle Type.
Digit 5 of the bar code has been decoded incorrectly.
47: Bar Code Invalid: Energy Correcon.
Digit 3 of the bar code has been decoded incorrectly.
48: Bar Code Invalid: Component Type.
Digits 1 and 2 of the bar code have been decoded incorrectly.
49: Bar Code Invalid: Check Digit.
Digit 24 of the bar code has been decoded incorrectly.
50: USB Memory: Disc full.
This fault will happen if the USB ash memory pen is full. Delete some les from the device.
52: USB Memory: File not found.
When performing a soware upgrade, the required le was not found on the memory drive.
Reload the upgrade les onto the memory drive.