DS-2TD2xxx-xxxx/xx Thermal and Optical Bi-Spectrum Network Camera User Manual
UM DS-2TD2xx-xxxx/xx Thermal 072020NA 19
2. Click .
3. Drag the mouse in live view to draw the area. Drag the corners of the red rectangle area to change its
shape and size.
4. Right click the mouse to stop drawing.
5. (Optional): Select one area, and click to delete it.
6. Click Save.
3.4 Manual Thermography
After enabling the manual thermography function of the device, you can click any position on live view to
show the real temperature.
1. Go to Configuration Local and set the Display Temperature Info. to Yes.
2. Go to Configuration Temperature Measurement Basic Settings.
3. Check Enable Temperature Measurement.
4. Click Save.
5. Go to the live view interface, select thermal channel, and click . Click any position on the interface
to show the real temperature.