Network Video Recorder User Manual 
82 
 
Figure 5. 18 Set Trigger Camera of VCA Alarm 
 
 
The PTZ Linking function is only available for the VCA settings of IP cameras. 
4.  Enter Record Schedule settings interface (Menu > Record > Schedule > Record Schedule), and then set VCA 
as the record type. For details, see step 2 in Chapter 5.2 Configuring Recording Schedule. 
5.6  Manual Recording 
Purpose: 
Follow the steps to set parameters for the manual record. Using manual record, you need to manually cancel the 
record. The manual recording is prior to the scheduled recording. 
Steps: 
1.  Enter the Manual settings interface. 
Menu > Manual 
Or press the REC/SHOT button on the front panel. 
 
Figure 5. 19 Manual Record 
 
2.  Enable the Manual Record. 
1)  Select Record on the left bar. 
2)  Click the status button before camera number to change    to  . 
3.  Disable manual record. 
Click the status button to change    to . 
 
Green icon    means that the channel is configured the record schedule. After rebooting, all the manual 
records enabled will be canceled.