You can set the authencaon interval of the same person when authencang. The same
person can only authencate once in the congured interval. A second authencaon will be
failed.
Max. Authencaon Failed Aempts Alarm/Alarm of Max. Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Enable Tampering Detecon
Enable the an-tamper detecon for the card reader.
Enable Card No. Reversing
The card No. will be in reverse sequence
aer enabling the funcon.
Communicaon with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Max. Interval When Entering Password
When you entering the password on the card reader, if the interval between pressing two
digits is longer than the set value, the digits you pressed before will be cleared
automacally.
OK LED Polarity/Error LED Polarity
Set OK LED Polarity/Error LED Polarity of the access control device according to the card
reader parameters. Generally, adopts the default sengs.
Set Door Parameters
Tap → Access Control → Door Parameters .