66
While enabled, the system will alert with buzzer for the tamper alarm. Regardless of whether it
is enabled or not, the tamper alarm will be normally pushed to Cloud (for APP) and ARC.
Panel Lockup Button
All functions of AX HYBRID PRO will be frozen after it is enabled. This function can only be
enabled by users with installer permission.
Alarm Duration
Set linked alarm voice prompt lasting time.
Wireless Supervision Loss
Detectors and peripherals whose heartbeat loss times exceed the set value will be shown as
offline.
Bypass on Re-Arm
While enabled, after the detector is bypassed, if its faults are restored and the linked area is
armed, the detector will automatically arm.
Motion Detector Restore
Motion detectors include all PIR detectors.
-Disable: No automatic restore.
-Immediate After Alarm: Motion detectors automatically restores immediately after the alarm
and reports to Cloud (for APP) and ARC.
-After Disarm: Motion detectors automatically restores after disarming and reports to Cloud (for
APP) and ARC
Jamming Sensitivity Settings
The device will detect RF interference and push messages when the RF interference interferes
with communication. You can adjust the detection sensitivity.
Enable PD6662
Enable PD6662 standard. Functions that do not meet the standard will not take effect.
Keypad Logout
After the keypad enters the programming page, if there is no key operation, it will exit the
programming page after reaching this time.
3.2.10 Fault Check
The fault check here is only for the control panel in the normal status.
The system determines whether to check the faults listed on the page. The system will only check
the fault that is selected.
Steps
1. On the device list page, tap the AX HYBRID PRO and then log in to the device (if required) to
enter the page.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-LP and is the answer not in the manual?

HIKVISION DS-PHA64-LP Specifications

General IconGeneral
Wi-FiYes
Wi-Fi frequency2.4 GHz
Wi-Fi standards802.11b, 802.11g, Wi-Fi 4 (802.11n)
Number of alarm zones64
Connectivity technologyWired & Wireless
Operating temperature (T-T)-10 - 40 °C
Number of simultaneous users62 user(s)
Operating relative humidity (H-H)10 - 90 %
Number of simultaneously connected devices (max)-
Batteries includedNo
Number of door/window sensors- pc(s)
Mounting typeWall
Product colorWhite
Housing materialPlastic
Battery life36 h
Alarm current2000 mA
Input voltage100 - 240 V
Battery voltage12 V
Battery capacity7000 mAh
Weight and Dimensions IconWeight and Dimensions
Alarm control panel weight997 g
Alarm control panel dimensions (W x D x H)261 x 86.4 x 199 mm