EasyManua.ls Logo

Hilti TE 2-M - 5 Operation; 6 Care and maintenance

Hilti TE 2-M
148 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 English
5 Operation
Fitting the side handle
CAUTION
Risk of injury! The depth gauge, if fitted but not used, might hinder the operator.
Remove the depth gauge from the tool.
CAUTION
Risk of injury! Loss of control over the rotary hammer drill.
Check that the side handle is fitted correctly and tightened securely. Check that the
clamping band is engaged in the groove in the tool.
2
TE 2-M
Fitting / removing the chuck
3
Fitting/removing the drill bit or other accessory: SDS chuck
Note
Use of unsuitable grease may cause damage to the product. Use only the
recommended grease supplied by Hilti.
4
TE 2-M
Fitting/removing the drill bit or other accessory: Quick-release chuck
5
Adjusting the depth gauge
Note
Always pay attention to the maximum length of the depth gauge.
6
Drilling with hammering action (hammer drilling)
7
TE 2-S
Light hammering action
7
TE 2
TE 2-S
Drilling
7
TE 2-M
Drilling in first gear or drilling in second gear
7
Forward / reverse
Risk of damage Actuation while the tool is running may result in damage to the gearing.
Do not operate the forward / reverse switch while the motor is running.
8
6 Care and maintenance
WARNING
Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to
the power outlet presents a risk of serious injuries including burns.
Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Printed: 04.10.2017 | Doc-Nr: PUB / 5170536 / 000 / 02