*2102964*
5.3 Chisel positioning 7
CAUTION
Risk of injury! Loss of control over the chisel direction.
Do not operate the tool when the selector switch is set to “Chisel positioning”. Turn the function selector
switch until it engages in the “Chiseling” position.
The chisel can be adjusted to 24 different positions (in 15° increments). This ensures that flat chisels
and shaped chisels can always be set to the optimum working position.
1.
Set the function selector switch to the “Chisel positioning” position .
2. Rotate the chisel to the desired position.
3.
Turn the function selector switch until it engages in the “Chiseling” position.
The product is ready for use.
5.3.1 Chiseling 8
Set the function selector switch to the “Chiseling” position .
5.3.2 Switching sustained operation on and off 9
When chiseling, the on/off switch can be locked in the “on” position.
1. Push the lockbutton for continuous operation forward.
2. Press the on/off switch as far as it will go.
The product then runs in sustained operating mode.
3. Push the lockbutton for continuous operation back.
The product switches off.
6 Detachable supply cord
6.1 Connecting the detachable supply cord
CAUTION
Risk of injury! Due to leakage current as a result of dirty contacts.
Connect the detachable electric connector to the electric tool only when it is clean and dry and when the
supply cord is unplugged from the power outlet.
1. Push the keyed, detachable electric plug connector into the socket as far as it will go, until it is heard to
engage.
2. Plug the supply cord into the power outlet.
6.2 Disconnecting the detachable supply cord
1. Unplug the supply cord from the power outlet.
2. Press the release button and pull the keyed, detachable electric plug connector out of the socket.
3. Pull the supply cord connector out of the power tool.
7 Care and maintenance
WARNING
Electric shock hazard! Attempting care and maintenance with the supply cord connected to a power outlet
can lead to severe injury and burns.
Always unplug the supply cord before carrying out care and maintenance tasks.
Care
Carefully remove any dirt that may be adhering to parts.
Clean the air vents carefully with a dry brush.
Printed: 12.12.2018 | Doc-Nr: PUB / 5283577 / 000 / 02

Other manuals for Hilti TE 50-AVR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti TE 50-AVR and is the answer not in the manual?

Hilti TE 50-AVR Specifications

General IconGeneral
DrillingYes
Chuck typeSDS Max
Product colorBlack, Red
Country of originGermany
Impact rate3180 bpm
Rated speed (max)360 RPM
Impact energy (max)6 J
Vibration level (hammer drilling)9 m/s²
Drilling diameter in concrete (max)40 mm
Optimum drilling diameter (concrete)16 - 32 mm
Input power1100 W
Power sourceAC
Power plug typeType C
Noise level108 dB
Quantity per shipping (inner) case1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Weight6100 g
Package depth3456 mm
Package width2000 mm
Package height4500 mm
Package weight4500 g