5.4 Requirements to be met by users
The tool is intended for professional use.
The tool may be operated, serviced and repaired only
by authorized, trained personnel. This personnel
must be informed of any special hazards that may
be encountered.
Always concentrate on the job you are doing. Pro-
ceed carefully and do not use the tool if your full
attention is not on the job.
Exercise your fingers during pauses between work
to improve the blood circulation in your fingers.
5.5 Personal protective equipment
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protection
and protective gloves when the tool is in use. Breath-
ing protection must be worn if no dust removal sys-
tem is used.
6. Before use
6.1 Use of extension cords
Use only extension cords of a type approved for the
application and with conductors of adequate cross sec-
tion. Failure to observe this point may cause the tool
to lose power and the extension cord may overheat.
Check the extension cord for damage at regular inter-
vals. Replace damaged extension cords.
Recommended minimum conductor cross section and
max. extension cord lengths:
Mains voltage Conductor cross section AWG
1.5 mm
2
2.0 mm
2
2.5 mm
2
3.3 mm
2
14 12
100 V 30 m 50 m
110–120 V 20 m 30 m 40 m 50 m 75 ft 125 ft
220–240 V 50 m 100 m
Do not use extension cords with 1.25 mm
2
or 16 AWG conductor cross sec-
tions.
Use of extension cords outdoors
When working outdoors use only extension cords that
are correspondingly marked and approved for outdoor
use.
6.2 Use of a generator or transformer
This tool may be powered by a generator or transformer
which fulfils the following conditions:
AC voltage, output power at least 2600 W.
The operating voltage must be within +5 % and
–15 % of the rated voltage at all times.
Frequency range 50–60 Hz, never above 65 Hz.
Automatic voltage regulation with starting boost.
Never operate other tools or appliances from the gen-
erator or transformer at the same time. Switching other
tools or appliances on and off may cause undervolt-
age and/or overvoltage peaks, resulting in damage to
the electric tool.
6.3 Fitting the side handle
1. Unplug the tool from the mains socket.
2. Release the side handle clamping band by turning
the handle in a counter-clockwise direction.
3. Fit the side handle clamping band over the chuck
and onto the cylindrical section at the front end of
the tool.
4. Pivot the side handle into the desired position.
5. Tighten the side handle securely to prevent inad-
vertent movement.
Wear ear
protection
Wear
protective
gloves
Wear
breathing
protection
Wear eye
protection
Wear a
hard hat

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti TE16 and is the answer not in the manual?

Hilti TE16 Specifications

General IconGeneral
BrandHilti
ModelTE16
CategoryRotary Hammer
LanguageEnglish

Related product manuals