8
Disposal
Most of the materials from which Hilti power tools are manufactured can be recycled. The materials must be cor-
rectly separated before they can be recycled. In many countries, Hilti has already made arrangements for taking
back your old electric tools for recycling. Please ask your Hilti customer service department or Hilti sales repre-
sentative for further information.
Should you wish to return the electric tool yourself to a disposal facility for recycling, proceed as follows: Dismantle
the tool as far as possible without the need for special tools. Use absorbent paper to wipe lubricated parts clean
and to collect the oil that runs out (total quantity approx. 50 ml ). This paper should also be disposed of correctly.
On no account should oil be allowed to enter the waste water system or to find its way into the ground.
The individual parts should be separated as follows:
Part / assembly Main material Recycling
Toolbox Plastic Plastic
Gear housing Plastic with Scrap metal
magnesium alloy / brass part
Bearing plate Magnesium alloy / brass Scrap metal
Grip, side handle Plastic Plastic
Motor housing Plastic Plastic
Grip cover Plastic Plastic
Fan Plastic Plastic
Motor (rotor and stator) Steel and copper Scrap metal
Supply cord Copper, elastomer sheath Scrap metal
Gearing parts, hammering mechanism parts Steel Scrap metal
Screws, small parts Steel Scrap metal
Troubleshooting
Symptom Possible cause Possible solution
The tool doesn’t start Fault in the electric power supply Plug in another electric tool and check
whether it starts
Defective supply cord or plug Have it checked by an electrical
specialist and replace if necessary
Switch defective Have it checked by an electrical
specialist and replace if necessary
No hammering action The tool is too cold Allow tool to reach the minimum
operating temperature
See section “Before use”
Function selection switch Set function selection switch
set to rotary drilling to hammer drilling
Tool doesn’t produce full Cross-section of the Use an extension cord of adequate cross-
power extension cord is inadequate sectional area. See section “Before use”
Control switch is not pressed fully Press the control switch as far as it will go
Function selection switch set Set function selection switch
to precision hammering action to hammer drilling
Forwards / reverse switch set Set forwards / reverse switch
to reserve when drilling to forwards
Drill bit cannot be released Chuck not opened fully Rotate the chuck (quick twist)
towards
()
and pull out the insert
tool.