1
CE0120
Hingmed
Wearable Ambulatory Blood Pressure Monitor
User Manual
(Apply toWBP-03D for home use)
Shenzhen Hingmed Medical Instrument Co., Ltd.
VERA/0
Date: March 15, 2015

Questions and Answers

  • L
    laurafullerSep 9, 2025
    What to do if HINGMED WBP-03D displays 'beyond the limit'?
    • M
      Miss Jaime Fields MDSep 9, 2025
      If your HINGMED Blood Pressure Monitor displays 'beyond the limit', it might be because the subject's pressure exceeds the device's limitations. Press the “start/stop” button to measure again. If the issue persists, consider using a monitor with a larger range.
  • L
    lopezdeborahAug 23, 2025
    What to do if HINGMED Blood Pressure Monitor shows system error?
    • C
      charles97Aug 23, 2025
      If your HINGMED Blood Pressure Monitor displays a system error, try restarting it. If the error occurs frequently, it might require professional maintenance.
  • A
    ajenkinsAug 25, 2025
    What to do if HINGMED WBP-03D Blood Pressure Monitor displays overtime error?
    • J
      Jennifer KellyAug 25, 2025
      If your HINGMED Blood Pressure Monitor shows an overtime error (measuring time beyond 120s in adult/child mode, 90s in neonatal mode), keep quiet and press the “start/stop” button to measure again.
  • A
    Adam HallAug 26, 2025
    What to do if HINGMED WBP-03D displays overpressure error?
    • L
      Linda YoungAug 27, 2025
      If your HINGMED Blood Pressure Monitor displays an overpressure error (cuff pressure beyond 290mmHg in adult mode, 247mmHg in child mode, and 145mmHg in neonatal mode), press the “start/stop” button to measure again.
  • M
    Melissa BowmanAug 28, 2025
    What to do if HINGMED Blood Pressure Monitor measurement result is not available?
    • J
      Jocelyn WilliamsAug 28, 2025
      If the measurement result is not available on your HINGMED Blood Pressure Monitor, press the “start/stop” button to measure again.
  • T
    Thomas ThomasAug 29, 2025
    What to do if HINGMED Blood Pressure Monitor shows no answer when the measurement command is sent?
    • S
      Sarah FosterAug 29, 2025
      If your HINGMED Blood Pressure Monitor shows no answer when the measurement command is sent, press the “start/stop” button to measure again.
  • M
    michael98Sep 18, 2025
    Why HINGMED Blood Pressure Monitor shows weak signal?
    • M
      Mr. Steven JonesSep 18, 2025
      If your HINGMED Blood Pressure Monitor displays a weak signal, it could be due to a weak pulse or a loose cuff. Check if the cuff is too loose and tighten it if needed.
  • P
    Patricia BarreraSep 18, 2025
    What to do if HINGMED WBP-03D shows air pressure error?
    • B
      Bruce SmithSep 18, 2025
      If your HINGMED Blood Pressure Monitor displays an air pressure error, it might be due to the inability to open the valve. Check whether the valve can work normally.
  • M
    Micheal ShortSep 7, 2025
    What to do if HINGMED WBP-03D Blood Pressure Monitor restarts measuring when the pressure is still above 15mmHg?
    • P
      Paul LopezSep 7, 2025
      If your HINGMED Blood Pressure Monitor restarts measuring when the pressure is still above 15mmHg, allow gassing and remeasure when the cuff pressure declines to below 15mmHg.
  • M
    Mason DiazSep 4, 2025
    What to do if HINGMED Blood Pressure Monitor shows overtime (beyond 180s)?
    • J
      jamessusanSep 5, 2025
      If your HINGMED Blood Pressure Monitor shows overtime (beyond 180s), remeasure.

Summary

Chapter 1 Preface

1.1 Brief Introduction to Ambulatory Blood Pressure Monitoring

Overview of ambulatory blood pressure monitoring, its benefits, and comparison to clinical measurements.

Chapter 2 Safety Requirements

2.1 Intended use

Defines the primary purpose and application of the wearable blood pressure monitor.

2.2 Contraindication

Lists conditions and situations where the blood pressure monitor should not be used to avoid harm.

2.3 Warnings

Details important precautions and potential risks associated with using the blood pressure monitor.

2.4 Notice

General notices regarding battery, measurement, environment, and maintenance practices.

Chapter 3 Product Introduction

3.1 Product composition

Lists the main unit and included accessories, as well as optional accessories.

3.2 Name and Function of Each Component

Details the host unit, its components, and their respective functions for user understanding.

Chapter 4 Product Installation and Use

4.1 Battery installation

Instructions on how to install and recharge the built-in Li-ion battery of the monitor.

4.2 Wear the monitor

Guidance on correctly wearing the monitor and cuff, starting measurements, and preparation for use.

4.3 Install system (Smart mobile terminal)

Guides users on setting up the mobile application and connecting it to the monitor via Bluetooth.

4.4 Execute Ambulatory Blood Pressure study (Smart mobile terminal)

Details the process of conducting a 24-hour ambulatory blood pressure study using the device and app.

Chapter 5 Troubleshooting and Maintenance

5.1 Troubleshooting

Lists common error codes and their corresponding resolutions for issues encountered with the monitor.

5.2 Maintenance

Provides guidelines for maintaining the monitor to ensure its safe and efficient long-term operation.

Chapter 7 EMC information

Guidance and manufactures declaration - electromagnetic emission

Information on the device's electromagnetic emissions and guidance for its use in different environments.

Guidance and manufactures declaration - electromagnetic immunity

Details on the device's electromagnetic immunity and guidance for its use in different environments.

Chapter 8 Warranty Card

The limited liability of guarantee

Outlines the warranty period, terms, conditions, and limitations for the Hingmed blood pressure monitor.