37
Checking Maximum, Minimum and Average Values (Recording Function – REC)
3.4
Checking Maximum, Minimum and
Average Values
(Recording Function – REC)
Use the recording function to display the maximum/minimum measurement
value, the average of the maximum and minimum, or the instantaneous value.
1
Select the current range.
2
Press the MAX/MIN key
while current is being
measured
.
The maximum, minimum, average or
instantaneous value for the period
from when the MAX/MIN key was last
pressed up to the present moment will
be displayed. The other data will be
retained in the internal memory. ([REC]
will ash)
[MAX], [MIN] and [AVE] displays Measurement value displayed
[MAX] Maximum value
[MIN] Minimum value
[AVE]
Average value = (maximum value +
minimum value)/2
None Instantaneous value
Pressing the MAX/MIN key during auto ranging ([AUTO])
xes the range at the current setting.
When you use the recording function, auto power-off will be
turned off automatically.