39
Checking Maximum, Minimum and Average Values (Recording Function – REC)
The elapsed time count will stops for as long as lights
steady.
Momentary power loss and power surges cannot be detected in
this mode.
The maximum, minimum or average value will be cleared when
the power is turned off.
The duration that the recording function can be used for depends
on the remaining battery capacity. Use a new layered-type alkaline
battery (6LR61) when using it for a long duration.
The lowest frequency that can be displayed is 30.0 Hz.
If you clamp the conductor after enabling the recording function,
there will be no input and so the minimum value will be zero. To
prevent this, clamp the conductor before pressing the MAX/MIN
key to enable the recording function.
If you take the jaws off the conductor with the recording
function still enabled, the input will stop and so the minimum
value will be zero. To prevent this, press the HOLD key to halt
the recording function before taking the jaws off the object.
Bar graph displays (BAR GRAPH)
You can switch the bar graph between different displays.
RMS value display
(instantaneous value)
Elapsed time (hours) [hour]
Elapsed time (minutes) [min]
Current range display
When you set one of the elapsed time displays, a segment in the
bar graph will ash to indicate the time that has elapsed since the
MAX/MIN key was last pressed.