EasyManua.ls Logo

Hioki dt4212 - Accuracy Table

Hioki dt4212
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
Accuracy Table
5.3 Accuracy Table
Accuracy warranty period 1 year
Regulated power supply range
2.4 V ± 0.15 V or more (until lights
up)
Accuracy guarantee for
temperature and humidity
23°C ± 5°C (73°F ± 9°F), 80%RH or less
(non-condensating)
Temperature characteristic Adds “Measurement accuracy × 0.1/°C”
(excluding 23°C ± 5°C (73°F ± 9°F)).
rdg. (reading or displayed value): The value currently being measured and
displayed on the measuring instrument.
dgt. (resolution): The smallest displayable unit, i.e., the input value that
causes the digital display to show a “1” as the least-signi cant digit.
1
AC voltage
Range
Accuracy
*1
Input impedance
40 to 500 Hz
400.0 mV
*2
±1.0% rdg. ±10 dgt.
11M
±2%
100 pF or less
4.000 V ±1.0% rdg. ±5 dgt.
40.00 V
±1.0% rdg. ±5 dgt.
10M
+2%
100 pF or less
400.0 V
1000 V
Overload protection: 1100 V DC/1100 V AC or 10
6
V • Hz (energized for 1 minute)
Transient overvoltage: 6000 V
Crest factor (Only the DT4212 (True RMS measurement model)): The crest
factor is 2 up to 2800 counts and reduces linearly to 1.5 at 4000 counts.
*1: The accuracy is speci ed in 1% or more of the range.
*2: Only the manual range.

Table of Contents