Working area definition
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 23
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
4.4 Working area definition system (WADS)
The LMI system has programmed functions for monitoring the working area in accordance with the
area of use of the crane:
easy to program by menus
functions can be used individually or in combination
acoustic alarm and display of a symbol when a programmed limit value is reached or exceeded
clear display of the programmed limit value in an information menu screen.
The “Working area definition” function described below is an aid for moving the crane
within adjustable boom ranges.
Reaching or exceeding a programmed limit value
does not stop the boom movements!
The crane driver alone is responsible for the safe operation of the crane!
Working area limits are indicated by the following symbols:
Limit type:
Radius
(min. and max.)
Height
Boom angle
(min. and max.)
Slew angle
(left and right)
"Virtual" wall
(up to 5 walls)
Symbols on
limit info page:
with active limits
displayed
Symbols in the
status display:
Constant =
limit active
Flashing=
Limit reached or
exceeded
refer to chapter:
4.4.1
4.4.2 4.4.3 4.4.4 4.4.5