Error Code Error Cause Elimination
• Pressure transducer is
defective.
• PDB variable for analog value
not supported
• Replace pressure transducer
• Setup of correct PDB variable
for analog value in DGA6.i.3
E12
Fallen below the lower
limit value in the
measuring channel
"pressure piston side"
• Electronic component in the
measuring channel is defective.
• Replace sensor unit
E13
Fallen below lower limit
value in the measuring
channel "pressure rod
side"
• refer to E12 • refer to E12
E14
Fallen below lower limit
value in measuring
channel "force"
• Force transducer defective
• Electronic component in the
measuring channel is defective.
• Replace force transducer
• Replace sensor unit
• Angle potentiometer defective
• PDB variable for analog value
not supported
• Replace angle sensor
• Setup of correct PDB variable
for analog value in DGA6.i.3
E15
Fallen below lower limit
value in measuring
channel "angle main
boom"
• Electronic component in the
measuring channel defective.
• Replace sensor unit
• Angle potentiometer defective • Replace angle sensor
E16
Fallen below lower limit
value in measuring
channel "angle 2"
• Electronic component in the
measuring channel defective.
• Replace sensor unit
• Length potentiometer defective • Replace length sensor.
E17
Fallen below lower limit
value "length telescope I
(+II)"
• Electronic component in the
measuring channel defective
• Replace sensor unit
E18
Front outrigger
overloaded
• Front outrigger overloaded •
• Cable between the central unit
and the slewing angle sensor
defective or loose. Water inside
the plug of the angle sensor
• 1-cannel slew sensor min. value
DGA 11.5.7 <> 0
• Check cable as well as plugs,
replace, if need be.
• move to allowed slew range
• Slewing angle potentiometer is
defective
• Replace slewing angle sensor
E1A
Fallen below lower limit
value in measuring
channel "slewing angle
1".
slew below allowed
range
• Electronic component in the
measuring channel defective
• Replace sensor unit
E1B
Fallen below lower limit
value in measuring
channel "slewing angle
2"
• refer to E1A
• refer to E1A
E1C
Fallen below lower limit
• Angle potentiometer defective • Replace angle sensor