Traffic control
Basic - L3P
Release
3.1
06/07
8.4
Prioritization
137
Fig. 37: Ethernet data packet with tag
Fig. 38: Tag format
t
min. 64, max. 1522 Octets
Preamble Field
Start Frame Delimiter Field
Destination Address Field
Source Address Field
Tag Field
Data Field
Length/Type Field
Data Field
Pad Field
Frame Check
Sequence Field
42-1500 Octets 4246671
t
4 Octets
User Priority, 3 Bit
Canonical Format Identifier
1 Bit
VLAN Identifier
12 Bit
Tag Protocol Identifier
2 x 8 Bit