22
Installation RSPE30/32/35/37
Release
16
04/2019
19 Temperature range S Standard +32 °F ... +140 °F (0 °C ...
+60 °C)
T Extended −40 °F ... +158 °F
(−40 °C ... +70 °C)
E Extended with
Conformal Coating
−40 °F ... +158 °F
(−40 °C ... +70 °C)
20 ... 21 Supply voltage CC 2 voltage inputs for redundant power supply
Rated voltage range DC:
24 V DC ... 48 V DC
K9 1 voltage input
Rated voltage range AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Rated voltage range DC:
60 V DC ... 250 V DC
KK 2 voltage inputs for redundant power supply
Rated voltage range AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Rated voltage range DC:
60 V DC ... 250 V DC
PP PoE 2 voltage inputs for redundant power
supply
Rated voltage range
47 V DC ... 57 V DC
PoE+ 2 voltage inputs for redundant power
supply
Rated voltage range DC:
53 V DC ... 57 V DC
22 ... 23 Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 5 on page 24.
24 ... 25 Software packages 99 Reserved
26 ... 27 Customer-specific
version
HH Hirschmann Standard
28 Hardware
configuration
S Standard
MFast MRP
PPRP
HHSR
D From software version 05.0 onward:
Hirschmann DLR
Note: You can exchange software with each other on the
following device variants:
M
P
H
R
Item Characteristic Character
istic value
Description
Table 4: Device name and product code