Input <admin> in the login line, and then press Enter.
Input <password>, and then press Enter.
Changing password
Change the password for the admin user ID.
1. Input configure terminal and press Enter to move to global
configuration mode.
2. Input username admin password
<new password> role admin enable
true, and then press Enter.
Logout
1. Input logout, and then press Enter.
Fibre Channel switch module initial configuration
This section describes how to configure Brocade 8 Gb/sec Fibre Channel
switch module and Brocade 16 Gb/sec Fibre Channel switch module.
Change the system administrator password, and create a new user ID and
password. For the procedure in detail, see Referenced Documents on page xiv
manuals in Hitachi Compute BladeFibre Channel SwitchAccessory DVD(EN).
Login
1. Start a terminal emulator to the switch module from the system console,
and then connect IP address configured at Management LAN port
configuration on page 2-14.
2. The system administrator's user ID and password have factory default
values. Input the following user ID and password to login.