5-2 
 
※For others errors not shown above, contact to your 
supplier or local Hitachi distributor or service station . 
  *1)STO function is not suitable for LH1 series. 
■Warning events 
※Regarding the warnings, please refer to Page4-8. Fixing 
the parameter details shown in the panel screen may 
end the warning. 
 
 
 
 
 
 
 
 
 
 
 
 
 
・Ground fault detected at main 
circuit voltage turning-on 
・Check for ground fault of the motor, wiring, etc. 
・Continued state of incoming high 
power   
・Review the power circumstances, such as the power 
supply capacity 
・Instantaneous power failure, 
control supply has dropped 
・If you wish to avoid the tripping, use the power loss retry 
function. 
・Abnormality in temperature 
detector circuit 
・Carry out counter measures for the inverter noise 
・Consecutive errors may cause a failure 
・Because of cooling-fan life span, 
internal temperature has raised   
・Change of the cooling-fan is necessary 
・Lower the carrier frequency 
・Internal temperature has 
increased   
・Requires a review of the installation circumstances 
・Lower the carrier frequency 
・Disconnection of the wiring in the 
supply side has occurred   
・Check the fastening of the input wiring with screws   
・Check that the 3 phases are correctly inserted 
・Suddenly current increase 
・Output wiring ground fault・Disconnection confirm 
・Check that the motor is not locked 
・Disconnection of the wiring in the 
motor side has occurred 
・Check the output wiring disconnection, motor insulation 
failure, …etc. 
・Check that the 3 phases are correctly inserted 
・Abnormal motor temperature 
・Improve the motor cooling circumstances 
・Use the overload restriction function 
・Check for the break-down of the thermistor 
・Check the thermistor settings 
・Check for the break-down of the brake and for the 
disconnection of the wiring for the [BOK] signal 
・Check the brake waiting time 
・During slow speed, current has 
increased   
・If torque is needed during slow speed, a review of the 
inverter capacity is necessary 
・Panel disconnection error 
・Check for the disconnection of the panel from the 
inverter 
・Noise counter-measures are necessary 
・RS485 communication error 
・Noise counter-measures are necessary 
・Check the communication setting 
・Battery replacement for the panel is necessary 
・There is an error in the EzSQ 
programme. 
・  For more information, contact to your supplier or local 
Hitachi distributor or service station . 
 
・There is an error in the option. 
・For more information, contact to your supplier or local 
Hitachi distributor or service station . 
 
・There is an error in the STO path 
*1). 
・For more information, contact to your supplier or local 
Hitachi distributor or service station .