7.1 400V class specifications
Model name
LH1-***H/****H
standard capacity
055
075
110
150
185
220
300
370
450
550
750
900
1100
1320
1600
Applicable motor capacity
(4 poles)(kW)
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
Output
Rated output
current(A)
14.0
17.0
23.0
30.0
39.0
45.0
60.0
72.0
88.0
105.0
142.0
168.0
208.0
253.0
305.0
Overload current
rating *1
120% 60sec / 150% 3sec
Rated output voltage
Three-phase(3 wire)380 to 460V (Corresponding to the incoming voltage)
Rated
capacity
(kVA)
400V
9.7
11.8
15.9
20.8
27.0
31.2
41.6
49.9
61.0
72.7
98.4
116.4
144.1
175.3
211.3
460V
11.2
13.5
18.3
23.9
31.1
35.9
47.8
57.4
70.1
83.7
113.1
133.9
165.7
201.6
243.0
Input
Rated input
current(A)
*2)
16.6
20.2
27.4
35.7
46.4
53.6
71.5
85.7
104.8
125.0
169.0
200.0
247.6
301.2
363.1
Rated input
AC voltage
Control power supply : Single-phase supply 380 to 460V (Permissible AC voltage 323 to 506) ,
50Hz(allowable variation range: 47.5-52.5Hz)/60Hz (allowable variation range:57-63Hz)
Main circuit power supply: Three-phase(3 wire) 380to 460V (Permissible AC voltage 323 to 506) ,
50Hz(allowable variation range: 47.5-52.5Hz)/60Hz (allowable variation range:57-63Hz)
Power supply
capacity
(kVA) *3)
12.7
15.4
20.9
27.2
35.3
40.8
54.5
65.3
79.8
95.3
128.8
152.4
188.7
229.5
276.7
Carrier frequency variation
*4)
0.5~10.0kHz
0.5~8.0kHz
Braking
Regenerative
Internal BRD circuit (external discharge resistor value)
*5
External regenerative braking unit
Minimum resistance
value(Ω)
70
70
35
35
24
24
20
15
15
10
10
-
-
-
-
Dimensions
*6)
H(height)(mm)
255
260
260
260
390
390
390
540
550
550
550
700
700
740
740
W(width)(mm)
150
210
210
210
245
245
245
300
390
390
390
390
390
480
480
D(Depth)(mm)
140
170
170
170
190
190
190
195
250
250
250
270
270
270
270
Protective structure
IP20 UL Open Type
Aprox. weight (kg)
3
6
6
6
8.5
8.5
8.5
22
31
31
31
41
41
53
53
*1) Electronic thermal protection is accordance to derating.
*2) The rated input current is the value when the drive is operated in the rated output current. The value of the impedance at the supply side changes
due to the wiring, breaker, input reactor, etc.
*3) The power supply capacity is the value of the rated output current at 440V. The value of the impedance at the supply side changes due to the wiring,
breaker, input reactor, etc.
*4) It is recommended to set the carrier frequency settings [bb101]/[bb201] equal or greater than the (maximum output frequency x 10)Hz.
For induction motor IM, it is recomended to set the carrier frequency to 2 kHz or more except V/f control. For synchronous motor (SM)/Permanent
magnet motor (PMM), it is recomended to set the carrier frequency to 8 kHz or more.
*5) Usually an external regenerative braking unit is required. However, with an optional built in chopper braking ciruit and external discharge resistor
can eliminate a external regenerative unit. The built-in chopper braking circuit is offered by order. In order to purchase, contact to the nearest sales
office
*6) The key height of keypad are exclued from dimensions. When an option is connected, the depth is increased. Refer to the each optional instruction.

Related product manuals