4. TROUBLESHOOTING [Protective Device]
Other
LCD Indication
What and How to Detect
Failure
Light
Detector
Shutdown
What Actions to Take
How to
Reset
History
code
Error
code
Heading Trouble Description
PROBLEM
Battery out
(BATTERY OUT)
Battery voltage low
ALARM
Blinks
CPU No
Disconnect the power and replace the
battery with a new one.
9.4
11
.
Press RESET
button.
64 E0.64
Scheduling operation error
(SCHEDULE SET ERR)
Start/stop time not set
yet
ALARM
Blinks
CPU No 3.3.5 󱦵
Press RESET
button.
62 E0.62
Lead/lag operation error
(MULTI-U SET ERR)
Setting error
ALARM
Blinks
CPU No
Check the wire and the operation
setting on the instrument panel.
Press RESET
button.
61 E0.61
RS-485 port error
(COM.ERR STOP)
Wiring connection or
setting error
SHUTDOWN
Blinks
CPU No (Note 4)
Press RESET
button.
65,
66, 67
E0.65,
66, 67
RS-485 port error
(COM.ERR ALM)
Wiring connection or
setting error
ALARM
Blinks
CPU No (Note 4)
Press RESET
button.
63X, 68X
E0.63X,
68X
FAILURE
[Vtype]
Control device error (SYSTEM ERR)
Controller error
SHUTDOWN
Blinks
CPU Yes page 38 (a)
Press RESET
button.
13 E0.13
Fan inverter error 57 E0.57
PCB error
(PCB ERR)
(ROM1)(RAM1) main
board memory error
SHUTDOWN
Blinks
CPU Yes
Disconnect the power and then
reconnect the power. If problem is
persists, change the PCB.
Press RESET
button.
43
47, 48
E0.43
47, 48
(ROM2)(RAM2) LCD
board memory error
41,
42 46
E0.41
42, 46
[Vtype]
Controller retry (SYSTEM RETRY)
After reputation of retry
action
SHUTDOWN
Blinks
CPU Yes
Check the power line, controller and air
end.
Press RESET
button.
44 E0.44
Interstage pressure sensor error
(PRESS.SNSR ERR 1)
PS1 disconnected
SHUTDOWN
Blinks
CPU Yes
Disconnect the power and check the
pressure sensor wire for tightness.
Press RESET
button.
33 E0.33
Discharge pressure sensor error
(PRESS.SNSR ERR 2)
PS2 disconnected
SHUTDOWN
Blinks
CPU Yes
Press RESET
button.
34 E0.34
Oil pressure sensor error
(PRESS.SNSR ERR 4)
PS4 disconnected
SHUTDOWN
Blinks
CPU Yes
Press RESET
button.
39 E0.39
2nd stage inlet
temperature sensor error
(TEMP.SNSR ERR 2)
TH2 disconnected
SHUTDOWN
Blinks
CPU Yes
Disconnect the power and check the
thermistor sensor wire for tightness.
Press RESET
button.
32 E0.32
1st stage outlet
temperature sensor error
(TEMP.SNSR ERR 3)
TH3 disconnected
SHUTDOWN
Blinks
CPU Yes
Press RESET
button.
35 E0.35
2nd stage outlet
temperature sensor error
(TEMP.SNSR ERR 4)
TH4 disconnected
SHUTDOWN
Blinks
CPU Yes
Press RESET
button.
36 E0.36
Oil temperature sensor error
(TEMP.SNSR ERR 5)
TH5 disconnected
SHUTDOWN
Blinks
CPU Yes
Press RESET
button.
37 E0.37
During Operation (Note 1)
LCD Indication
What and How to Detect
Failure
Light
Detector
Shutdown
What Actions to Take
How to
Reset
History
code
Error
code
Heading Trouble Description
ALARM
Clogging of air intake fi lter
(AIR FILTER)
Pressure differential of -0.72 psi
-
4.98 kPa or more
ALARM
Blinks
Pressure
differential
sensor
No 9.4
1
Automatically
reset.
21 E0.21
1st stage discharge air temperature
(DIS. TEMP. 1)
About 428 [410]
220 [210]℃〉 or higher
ALARM
Blinks
Thermistor
No 4.2
Automatically
reset.
25 E0.25
2nd stage discharge air temperature
(DIS. TEMP. 2)
󱾀
For working pressure of
100psi 0.69MPa model: About
437 [419] 225 [215]℃ or higher
󱾀
For working pressure of
125psi 0.86MPa model : About
491 [473] 255[245]℃ or higher
ALARM
Blinks
Thermistor
No 4.2
Automatically
reset.
26 E0.26
2nd stage suction air
temperature
(2ND-S. TEMP)
154 [149]
68 [65]℃ or higher
ALARM
Blinks
Thermistor
No 4.2
Automatically
reset.
2B E0.2B
Oil temperature
(OIL TEMP)
154 [149]
68 [65]℃ or higher
ALARM
Blinks
Thermistor
No 4.2
Automatically
reset.
28 E0.28
[Fixed Speed type]
Oil pressure
(LOW O.P.)
15 psi 0.10MPa or lower
ALARM
Blinks
Pressure
sensor
No 4.2
Automatically
reset.
2C E0.2C
[Built-in dryer type]
(DRYER)
When set the ALARM for the
dryer failure. See page 27
ALARM
Blinks
Pressure
sensor
No -
Automatically
reset.
2E E0.2E
Main motor temperature
(FIN-T) [Vtype]
203 95
or more on the
motor cooling fi n
ALARM
Blinks
Thermistor
No 9.4
14
Automatically
reset.
81 E0.81
Load/unload cycle time over
(L COUNT OVER)
1,000,000 cycles
ALARM
Blinks
Pressure
sensor
No
Replace suction throttle valve
consumable parts and Blow off
solenoid valves.
Hold down the
REMOTE and press the
SELECT/WIDE button
for 7 seconds or more.
51 E0.51
Notes
(1) If 2-value is indicated, the value in the [ ] is for water-cooled type.
(2) Depends on the specification, reverse phase relay is used.
(3) The air compressor using reverse phase relay, such as for 460 V/60 Hz, indicates a phase-lacking connection as reversal phase.
(4) Communication error details:
Port 1 (65) =Main circuit communication (Vtype), Port 2 (66)=Fan inverter communication (Air-cooled type)
Port 3 (67)= LCD communication, Port 4 (68)= Multiple unit control communication, Port 5 (63)= External communication
(5) If the thermistor is disconnected, override operation is not available. Contact the local HITACHI distributor/master dealer or representative office.

Other manuals for Hitachi NEXT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi NEXT Series and is the answer not in the manual?

Hitachi NEXT Series Specifications

General IconGeneral
BrandHitachi
ModelNEXT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals