wiring may be cut or burnt. Protect the wiring from the
heat and the edges with the RC cover -A-.
• Check that
the high pressure switch (PSH) does not make contact with the aluminium sheet -G- of the RC
cover -A-.
c. Fit the Sound proof cover -K- firmly with two tacks -L- to avoid water entering into the free space between the RC cover
-A- and the upper sound proof cover -K-.
N O T E
• Make sure that the wiring of the Td thermistor pull out from the RC cover -A- through the dent part -L-
• Make
sure
that the wiring of the pressure switch (PSH) pull out from the RC cover -A- through the dent part -
M-
18 Carry out the final check for the wiring conditions referring to the drawing below.
C A U T I O N
Make sure
that all wires do not contact with the compressor, piping or plate edges. If it contacts, wire breakage of
fire may occurred.
10 Servicing
306
SMGB0065 rev. 1 - 12/2010