10.13 Removing the
high pressure switch, high pressure sensor and low pressure
sensor
D A N G E R
• Turn OFF all the power source switches.
N O T E
• For servicing use the following tools:
- Pliers. - Adjustable wrench or spanner.
- Phillips screw driver. - Burner.
1 Remove the front service cover as described in the procedure Removing the front service cover, see on page 292.
2 The
high
pressure switch -A- (PSH1) and -B- (PSH2), the high pressure sensor -C- (Pd) and the low pressure sensor
-D- (Ps) are fixed in the position shown in the figure.
A
C
D
C
D
B
A
RAS - (8-12) FSXN RAS - (14-18) FSXN
10 Servicing
318
SMGB0065 rev. 1 - 12/2010