11.9 Reactor (DCL1 and DCL2)
This part is used to change the alternating current to direct current for the inverter.
DCL1
Item Specifications
Condition 1.0 mH ± 10% (at 1 Khz)
Rated current 30 A
Direct current resistance
22.8 mΩ ± 20% (at 20 °C)
Allowed temperature range Maximum 60 °C
DCL2
Item Specifications
Condition 3.0 mH
Rated current 10 A
Direct current resistance
0.13 Ω ± 10% (at 25 °C)
Allowed temperature range -10 °C to 180 °C
N O T E
All measurements are in mm.
60
47
58
74
4-5x10
61.6
60
800
Lead Wire Length
11 Electrical checks of the
main parts
345
SMGB0065 rev. 1 - 12/2010