Hitachi RPI-4.0FSG1 - OPTIONAL FUNCTION; 4. OPTIONAL FUNCTION; 4.1 Indoor Unit; 4.1.1 Remote Control ON;OFF Function

Hitachi RPI-4.0FSG1
384 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. OPTIONAL FUNCTION .............................................................................................................................. 4-1
4.1 Indoor Unit
(For RPF(I)-FSG(E), RPK-FSGM(6), RPC-FSG1 (Before Alteration) and RPI (8, 10HP) Series) .... 4-1
4.1.1 Remote Control ON/OFF Function ............................................................................................... 4-1
4.1.2 Power Supply ON/OFF 1 (Automatic Operation When Power Supply ON).................................. 4-5
4.1.3 Power Supply ON/OFF 2 (Restarting Function After Power Failure) ............................................ 4-5
4.1.4 Control by Field-Supplied Room Thermostat ............................................................................... 4-6
4.1.5 Operation Control by Remote Temperature Sensor (Except for RPK-FSGM Series) .................. 4-7
4.1.6 Cooling or Heating Operation Mode Setting Change by External Input (Level Signal Input) ....... 4-7
4.1.7 Picking Up Operation Signal......................................................................................................... 4-8
4.2 Indoor Unit (For RPI (0.8 to 5.0HP), RCI, RCD, RPC (After Alteration) and KPI Series) ................... 4-11
4.2.1 Input and Output Setting of Indoor PCB Connector ..................................................................... 4-11
4.2.2 Remote Control Thermistor Function............................................................................................ 4-13
4.2.3 Remote Control ON/OFF Function ............................................................................................... 4-14
4.2.4 Power Supply ON/OFF 1 (Automatic Operation When Power Supply ON).................................. 4-18
4.2.5 Power Supply ON/OFF 2 (Restarting Function After Power Failure) ............................................ 4-18
4.2.6 Control by Field-Supplied Room Thermostat (Except for KPI Series) .......................................... 4-19
4.2.7 Operation Control by Remote Temperature Sensor (Except for KPI Series) ................................ 4-20
4.2.8 Cooling or Heating Operation Mode Setting Change by External Input (Except for KPI Series).. 4-20
4.2.9 Precooling/Preheating Operation (KPI Series Only)..................................................................... 4-21
4.2.10 Picking Up Operation Signal ......................................................................................................... 4-21
4.3 Outdoor Unit....................................................................................................................................... 4-25
4.3.1 Demand ........................................................................................................................................ 4-27
4.3.2 Forced Stoppage .......................................................................................................................... 4-27
4.3.3 Demand Current Control (Only for 24 and 30HP) ........................................................................ 4-28
4.3.4 Fixing Operation Mode ................................................................................................................. 4-28
4.3.5 Snow Sensor ................................................................................................................................ 4-29
4.3.6 Defrosting Condition Changeover ................................................................................................ 4-30
4.3.7 Indoor Fan Control during Thermo-OFF at Heating ..................................................................... 4-30
4.3.8 All Season Heating Operation ...................................................................................................... 4-31
4.3.9 All Season Cooling Operation ...................................................................................................... 4-31
4.3.10 Night Shift (Low Sound) Operation ................................................................................................ 4-32
4.3.11 Picking Up Signals from Outdoor Unit Printed Circuit Board ........................................................ 4-33
4.4 Remote Control Switch, PC-P1H and PC-2H2 .................................................................................. 4-35
4.4.1 Name of Part ................................................................................................................................ 4-35
4.4.2 Simultaneous Operation ............................................................................................................... 4-36
4.4.3 Operation System with Two Remote Control Switches ................................................................ 4-38
4.4.4 Optional Function Setting ............................................................................................................. 4-40
4.4.5 Optional Functions of Remote Control Switch .............................................................................. 4-43
4.4.6 Indication of Address (ADDS) and Refrigerant Cycle Number (RN) ............................................. 4-47
4.5 Wireless Remote Control Switch, PC-LH3......................................................................................... 4-48
4.5.1 Name of Part ................................................................................................................................ 4-48
4.5.2 Identifying of Indoor Units Installed Side By Side ......................................................................... 4-49
4.5.3 Simultaneous Operation ............................................................................................................... 4-50
4.5.4 Emergency Operation................................................................................................................... 4-52
4.5.5 Optional Function Setting (In Case of PC-RLH4, PC-RLH5 and PC-RLH7) ................................ 4-53
4.5.6 Optional Functions of Wireless Remote Control Switch ............................................................... 4-54
4.6 7-Day Timer, PSC-5T ......................................................................................................................... 4-55
4.7 Central Station, PSC-5S .................................................................................................................... 4-56