S1 series standard inverter
-155-
Function
code
Name
Detailed parameter description
Default
value
Modify
voltage
on
model
P29.05
Inverter rated
current
0.06000.0A
Depend
on
model
P29.06
Dead timezone
2.0us15.0us
Depend
on
model
P29.07
Over-voltage
point
0.0V2500.0V
Depend
on
model
P29.08
Under-voltage
point
0.0V2000.0V
Depend
on mode
P29.09
Over-current
point
10.0%250.0%
220.0%
P29.10
Voltage
calibration
coefficient
10.0%250.0%
100.0%
P29.11
Current
calibration
coefficient
10.0%250.0%
100.0%
P29.12
Factory time
setting
065535h
0h

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi S1 Series and is the answer not in the manual?

Hitachi S1 Series Specifications

General IconGeneral
Output Frequency0 - 400 Hz
Overload Capacity150% for 60 seconds
Frequency50/60 Hz
Control MethodSensorless Vector Control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS485, Modbus RTU
Output Voltage3-Phase 200-240VAC, 3-Phase 380-480VAC (Matches Input Voltage)
Cooling MethodFan Cooled