26
B043 Torque limit (3) (reverse-driving in
4-quadrant mode)
150.
B044 Torque limit (4) (forward-regenerating in
4-quadrant mode)
150.
B045 Torque limit LADSTOP enable
00 Disable 01 Enable
00
B046 Reverse Run protection enable
00 Disable 01 Enable
00
B050 Controlled deceleration and stop on power loss
00 Disable 01 Enable
00
B051 DC bus voltage trigger level during power loss 0.0
B052 Over-voltage threshold during power loss 0.0
B053 Deceleration time setting during power loss 1.00
B054 Initial output frequency decrease during power
loss
0.00
B080 [AM] terminal analog meter adjustment 180
B081 [FM] terminal analog meter adjustment 60
B082 Start frequency adjustment 0.50
B083 Carrier frequency setting 5.0
B084 Initialization mode (parameters or trip history)
00 Trip history clear
01 Parameter initialization
02 Trip history clear and parameter initializa-
tion
00
B085 Country code for initialization
00 Japan version 01 Europe version
02 US version 03 (reserved)
01 / 02 / 00
B086 Frequency scaling conversion factor 1.0
B087 STOP key enable
00 Enable 01 Disable
00
B088 Restart mode after FRS
00 Restart from 0Hz
01 Restart from frequency detected from
actual speed of motor
00
B090 Dynamic braking usage ratio 00
B091 Stop mode selection 00
B092 Cooling fan control
00 Fan always ON
01 Fan ON during Run, OFF during Stop
00
Func.
Code
Name / Description
Default
Value
–FE/FU/FR
Set
Value