Chapter 4 List of Data Settings 
 
4 - 14 
 
Default 
Code  Function name  Monitored data or setting 
_F/_FF _FUF 
Setting 
during 
operation 
(allowed or 
not) 
Change 
during 
operation 
(allowed or 
not) 
H001 Auto-tuning Setting 
00 (disabling auto-tuning), 01 (auto-tuning without rotation), 02 
(auto-tuning with rotation) 
00 
¯  ¯ 
H002  Motor data selection, 1st motor 
00 (Hitachi standard data), 01 (auto-tuned data),   
02 (auto-tuned data [with online auto-tuning function]) 
00 
¯  ¯ 
H202  Motor data selection, 2nd motor 
00 (Hitachi standard data), 01 (auto-tuned data),   
02 (auto-tuned data [with online auto-tuning function]) 
00 
¯  ¯ 
H003  Motor capacity, 1st motor  0.20 to 90.00 (kW)   <0.20 to 160. (kW)>  Factory setting 
¯  ¯ 
H203  Motor capacity, 2nd motor  0.20 to 90.00 (kW)    <0.20 to 160. (kW)>  Factory setting 
¯  ¯ 
H004  Motor poles setting, 1st motor  2, 4, 6, 8, 10 (poles)  4 
¯  ¯ 
H204  Motor poles setting, 2nd motor  2, 4, 6, 8, 10 (poles)  4 
¯  ¯ 
H005  Motor speed constant, 1st motor  0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)  1.590 
{  { 
H205  Motor speed constant, 2nd motor 0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)  1.590 
{  { 
H006 
Motor stabilization constant, 1st 
motor 
0. to 255.  100. 
{  { 
H206 
Motor stabilization constant, 2nd 
motor 
0. to 255.  100. 
{  { 
H306 
Motor stabilization constant, 3rd 
motor 
0. to 255.  100. 
{  { 
H020  Motor constant R1, 1st motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H220  Motor constant R1, 2nd motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H221  Motor constant R2, 1st motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H221  Motor constant R2, 2nd motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H222  Motor constant L, 1st motor  0.01 to 99.99, 100.0 to 655.3 (mH)  Depending on motor capacity 
¯  ¯ 
H222  Motor constant L, 2nd motor  0.01 to 99.99, 100.0 to 655.3 (mH)  Depending on motor capacity 
¯  ¯ 
H223  Motor constant Io  0.01 to 99.99, 100.0 to 655.3 (A)  Depending on motor capacity 
¯  ¯ 
H223  Motor constant Io, 2nd motor  0.01 to 99.99, 100.0 to 655.3 (A)  Depending on motor capacity 
¯  ¯ 
H224  Motor constant J  0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. (kgm
2
)  Depending on motor capacity 
¯  ¯ 
H224  Motor constant J, 2nd motor  0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. (kgm
2
)  Depending on motor capacity 
¯  ¯ 
H030  Auto constant R1, 1st motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H230  Auto constant R1, 2nd motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H231  Auto constant R2, 1st motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H231  Auto constant R2, 2nd motor 
0.001 to 9.999, 10.00 to 65.53 (Ω) 
Depending on motor capacity 
¯  ¯ 
H232  Auto constant L, 1st motor  0.01 to 99.99, 100.0 to 655.3 (mH)  Depending on motor capacity 
¯  ¯ 
H232  Auto constant L, 2nd motor  0.01 to 99.99, 100.0 to 655.3 (mH)  Depending on motor capacity 
¯  ¯ 
H233  Auto constant Io, 1st motor  0.01 to 99.99, 100.0 to 655.3 (A)  Depending on motor capacity 
¯  ¯ 
H233  Auto constant Io, 2nd motor  0.01 to 99.99, 100.0 to 655.3 (A)  Depending on motor capacity 
¯  ¯ 
H234  Auto constant J, 1st motor  0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. (kgm
2
)  Depending on motor capacity 
¯  ¯ 
Control constants 
H234  Auto constant J, 2nd motor  0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999. (kgm
2
)  Depending on motor capacity 
¯  ¯ 
(Note)<>indicate the setting range of 90 to 160kW