Chapter 6. Character Print
6-31
Chapter 6.
(2) Operation
The following shows how to set 0.3048 in [Multiplier] for printing with feet to meter conversion
(1 foot = 0.3048 m).
[Note]
To return to the normal count, input an invalid character in [Multiplier] to make the multiplier invalid.
When a barcode is set in a count print item, the input area of [Multiplier] is masked, preventing you
from inputting any value.
An integer value can be input in [Multiplier].
No alphabet characters, symbols, or user patterns can be input in [Multiplier].
Input Count.
Count input screen (printing count multiplication)
Press Count conditions.
The [Count conditions] screen appears.
Press
or
in the print description edit area to change the target count block.
Press
in the count conditions to change the [Count conditions] screen.
Input "0.3048" in [Multiplier].
1
Count conditions
2
3
4
5