Battery unit
Battery lifetime
The battery life time is aected by the battery temperature. The battery temperature
changes depending on the intake temperature and height of the storage system, the
conguration, operation of the controller boards and drives, charge-discharge count and
others. The battery lifetime will be three to ve years.
Treatment
Use the storage system in a place where the ambient temperature is 86°F (30°C) or less
on average.
Periodic parts replacement is required. If you have a maintenance service contract, parts
are replaced periodically according to the terms of the contract.
Note: The battery pr
otects the data in the cache memory in an emergency,
such as a sudden power failure. In these cases, follow the normal power
down procedure. If not, the battery might reach its lifespan earlier than
expected and become unusable within three years. When replacing the
battery, follow the given procedure for disposing a used battery.
Replacement period
The battery lifetime (intake temperature is 30 degrees C or less.) in the standard
environment is as shown below.
Storage System Intake
Temperature CBSS CBSL
Up to 24 degrees Celsius 5 years 5 years
Up to 30 degrees Celsius 5 years 4 years
Up to 34 degrees Celsius 4 years 3 years
Up to 40 degrees Celsius 3 years 2 years
Removing cables
Observe the following instructions when removing cables form the storage system.
To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove
the SAS cable (2).