CONFIGURING SPEED CONTROL METHOD
Detroit Hoist VFD controls come factory pre-configured for 2-Step speed control unless otherwise specified during the ordering
process.
Use the chart below to configure the speed control method that is required.
Speed Control Method
Parameters
Values
2-Step P108 0
2-Step Infinitely Variable P108 1
3-Step
P108 2
P113 1
C006 61
3-Step Infinitely Variable
*Note - 3-step i
nfinitely variable
uses the 2
nd
step as a frequency
hold.
P108 3
P113 1
C006 61
0-10V Analog P108 4
4-20mA P108 5