36
11. 4 TRANSMISSION BELT.
The belt should be inspected yearly for wear. Replace if worn.
12.0 FAULT FINDING.
Fault Possible cause
Machine fails to start. Circuit protector is in open position – check fuse or
miniature circuit breaker.
Mixer is overloaded.
Wire cage is not in the closed position.
Bowl is not in closed (locked) position.
Agitator touches bowl. Bowl is not in closed (locked) position.
Improper agitator clearance – see Maintenance for
adjustment procedure.
Agitator is not installed properly.
Planetary seal squeaks. Seal requires occasional lubrication – see Maintenance.
Time displays error code (Erxx) If the error code is flashing – wait for mixer to clear error
condition.
If mixer continues to stop and timer displays flashing
error code, disconnect electrical power from mixer for 1
minute, and then reconnect.
If symptoms still exist, contact your local Hobart Service
office.
Alternated message of "b_in" on
SPEED display.
Bowl is not in all the way.
If message of "b_in" appears again after a corrective
action, disconnect electrical power from mixer for 1
minute, and then reconnect.
If symptoms still exist, contact your local Hobart Service
office.
Alternated message of "b_up" on
SPEED display.
Bowl is not up all the way.
If message of "b_up" appears after a corrective action,
disconnect electrical power from mixer for 1 minute, and
then reconnect.
If symptoms still exist, contact your local Hobart Service
office.
Alternated message of "b_gd" on
SPEED display
Wire cage is not closed completely.
If message of "b_gd" appears after a corrective action,
disconnect electrical power from mixer for 1 minute, and
then reconnect.
If symptoms still exist, contact your local Hobart Service
office.
Message of "HI" and "LOAD" on
displays.
Make sure you are not using STIR to develop dough
product.