Stack’d Series HOMEGRID Technical
Page 25 Chapter 6: Installation
Warning! All wiring must be performed by professionals. warning! It is very important to connect the battery
with proper cable for the safe and efficient operation of the system. To reduce the risk, use the correct cable and
terminal sizes recommended below.
3)Each system will be equipped with a positive terminal and a negative terminal. The two
connectors are not connected with cables, so users can connect wires according to actual
application needs.
Positive connector Negative connector
4) Communication connecting line between system and inverter(Optional)
5.2. Installation Location
Make sure that the installation location meets the following conditions:
◆The area will not puddle water or be folded.
◆The floor is flat and level.
◆There are no flammable or explosive materials.
◆The ambient temperature is within the range from 0°C to 50°C.
◆The temperature and humidity is maintained at a constant level.
◆There is minimal dust and dirt in the area.
◆The distance from heat source is more. than 2 meters.
◆The distance from air outlet. of inverter is more than 0.5 meters.
◆Do not install outside directly.
◆Do not cover or wrap the battery case or cabinet.
◆Do not place where there are children or pets.
◆Do not install where it will be in direct sunlight.
◆There is no ventilation required for ESS, but due to the heat given off from the battery and
inverters take note when installation in a small space or closed off area. Avoid areas of high
salinity, humidity or temperature.
If the ambient temperature is outside the operating range, the battery pack stops operating to
protect, itself. The optimal temperature range for the battery pack to operate is 0°C to
55°C.Frequent exposure, to harsh temperatures may deteriorate the performance and life of the
battery pack.
CAUTION