Stack’d Series HOMEGRID Technical
Page 20 Chapter 4: How to match communication with Inverter
3. How to match communication with Inverter
3.1. Supported brands
At present, the energy storage products of our company have completed matching tests with
some series inverters of the following brands, and we will continue matching tests with inverters
of other companies. Please check our official website for the latest list of supporting brands.
3.2. Inverter matching list
The list tab only lists the inverter manufacturers one of the same series products, general
inverter manufacturers in the same series of other products, the communication protocol are the
same, so our battery can be communicated with the other products of same series inverter, if
encounter a series of products can't communication, please contact us.
The following inverter matching list may not be up to date. The list may change according to
the software version upgrade, and the reference manual may does not change immediately
according to the software version upgrade. Therefore, if the user wants to get the latest inverter
matching support, please browse our the official website to check the relevant documents。
The inverter manufacturer may upgrade its software version, which may cause problems in the
communication between our battery and the inverter. Therefore, before communicating with
the inverter, please confirm whether the software version of the inverter is consistent with the
list. If not, please contact us.
Communication
mode
Brand Type Protocol Version
Growatt
SPF12KT HVM V1.22 RS485
SPH3000 V1.26 CAN
Studer Xtender-XTH-8000-48 V1.0.3 Xcom-CAN
Sofar HYD5000-ES V6.0 CAN
Solis RHI-5K-48ES V1.2 CAN
Goodwe GW5048-EM V1.5 CAN
Victron MultiPlus-II V6.0 CAN
SMA S16.0H-12 V2.0 CAN
Sermatec SMT-5K-TL-UN V1.2 CAN
Schneider Conext Gateway V2.0 CAN
Li_PLUS ZR Standard V1.2 CAN
Sol-ark Sol-ark-12k V1.31 CAN