OPERATION
54
6. Press the GFCI RESET button:
The green GFCI indicator will light continuously.
If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
When the GFCI RESET button pops out or the green GFCI indicator does not lit
during operation:
Unplug all appliances from the GFCI protected receptacle.
Press the GFCI RESET button.
If the GFCI cannot be reset, the GFCI is faulty. Contact an authorized
Honda Power Equipment dealer.
If the GFCI RESET button extends, this usually indicates a faulty power
tool, appliance, or cord. If that occurs, perform operation check steps 1
through 6 to verify that the GFCI is in proper working order. If the GFCI
tests correctly, then the fault is likely to be in the power tool, appliance,
or cord. Repair or replace the faulty power tool, appliance, or cord before
further use.
GFCI RESET BUTTON
GFCI INDICATOR
31Z238200.book 54 ージ 020年2月20日 木曜日 午前10時57

Table of Contents