Installation instructions / ACS-2 plus 23
8. Mounting
8.1 Installation site
The installation site of the central unit must meet the following conditions:
* within the indoor area of a building
* within the secured area
* easily accessible
* no extraordinary environmental conditions, e.g., aggresive vapors, high
humidity, etc.
* mounting at eye level
* not visible from the outside
* sufficient strength to resist being pulled off
* sufficient lateral distance to adjacent devices
* inside wall of the secured zone – if the device can only be mounted on the outside wall,
break-through monitoring might be required.
8.2 Mounting ACS-2 plus