EasyManua.ls Logo

Honeywell ACS-2plus - 17 Connections; Technical Data; Connections; Technical Data 026547, ACS-2 Plus, 230 V Version; Technical Data 026548, ACS-2 Plus, 12 V Version

Honeywell ACS-2plus
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90 Installation instructions / ACS-2 plus
17. Connections / technical data
17.1 Connections
Interface to the host system: 1 x interface slot inserted with:
- RS232 interface (026840.03)
- RS485 interface (026692, 026693)
- Ethernet interface (026840.29)
- Current-Loop interface (026840.16)
Keypad: 2 x external keypads with 2-wire technique connectable.
(The keypad can also be combined with a reader.)
Reader: 2 x external clock data readers connectable.
Supported reader types:
- contactless reader
- magnetic card reader
- chip card reader
Relays: 2 x door strike relays, max. 1.25 A / 24 V (Observe notes in chapter 15.4.1!)
1 x alarm relay
1 x tamper relay
Outputs: 2 x semiconductor outputs
1 x watchdog output (semiconductor)
Inputs: 8 x alarm line inputs
4 x semiconductor inputs (e.g., door strike key, monitoring contact)
Housing monitoring: 1 x cover contact (tamper)
Extensions: 1 x universal slot for RAM extension and future applications.
Battery support: 1 x 018002 (2.0 Ah)
17.2 Technical data 026547, ACS-2 plus, 230V version
Rated operating voltage 230 V AC
Operating voltage range 230 V AC -15% to +10%
Mains frequency 60 - 40 Hz
Power comsumption 24 VA
Output voltage U
ext.
12 V DC not stabilized
Maximal current drain 1,0 A
Maximal charging current 120 mA
Allowed battery capacity 2.0 Ah
No. of batterys connectable 1 max.
Battery monitoring permanently with temperature-controlled charging current
Operating temperature range 0EC to +45EC
Storage temperature range -25EC to +70EC
Protection class accord. to DIN40050 IP40
Environmental class accord. to VdS II
Housing dimensions in mm 250 x 210 x 100
17.3 Technical data 026548, ACS-2 plus, 12V version
Rated operating voltage 12 V DC
Operating voltage range 10 V DC to 15 V DC
Maximum residual ripple 35 mV
Current (typical) 200 mA
Max. current consumption with U_b 400 mA
Operating temperature range -0°C to +45°C
Storage temperature range -25°C to +70°C
Protection class according to DIN 40050 IP40
Environmental class according to VdS II
Contact rating of the relays 30 V DC/1A
Dimensions of the housing in mm 250 x 210 x 100

Table of Contents