EasyManua.ls Logo

Honeywell ADEMCO 4110XM - EntryExit Delays; Delay Settings Explained

Honeywell ADEMCO 4110XM
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data Field Programming
- 9 -
6
66
658
Zone 8 Alarm Report Code (Duress)
0 = No Report, 1-9, B-F (as described above).
Console Panic: Key B or *+#
6
66
659
NOT USED
(must be set to “00”)
6
66
660
Trouble Report Code
0 = No Report, 1-9, B-F (as described above).
Sent if zone has a trouble condition.
6
66
661
Bypass Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when a zone is manually bypassed.
6
66
662
AC Loss Report Code
0 = No Report, 1-9, B-F (as described above).
Sent at a random time delay up to 1 hour. If AC is
restored before the report goes out, no report will be
sent.
6
66
663
Low Battery Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when the system’s backup battery has a low-battery
condition.
6
66
664
Test Report Code
0 = No Report, 1-9, B-F (as described above).
Sent periodically to test that the communicator and
phone lines are operational.
6
66
665
Open Report Code
0 = No Report, 1-9, B-F (as described above).
Sent upon disarming the system.
6
66
666
Close Report Code
0 = No Report, 1-9, B-F (as described above).
2nd digit is automatically sent as the user number if
expanded or 4+2 reporting is selected.
Sent upon arming the system.
6
66
667
NOT USED
(must be set to “00”)
6
66
668
Cancel Report Code
0 = No Report, 1-9, B-F (as described above).
Sent upon disarming the system after an alarm has
occurred.
6
66
669
Group Restores for Trouble and Bypass
0 = No (Report for each restore); 1 = Yes (Report after all
zones restored)
Note: “1” not applicable to Contact ID Reporting
Restore Report Codes (
6
66
6
69-
6
66
6
75)
6
66
670
Alarm Restore Report Code
0 = No Report, 1-9, B-F (as described above).
2nd Digit is automatically sent as the 2nd digit of the
zone alarm report code programming in *50-*59, if
Expanded or 4+2 reporting is selected.
Sent when an alarm zone is restored to non-faulted
state.
6
66
671
Trouble Restore Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when a trouble in a zone is restored.
6
66
672
Bypass Restore Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when a zone that has been bypassed is unbypassed.
6
66
673
AC Restore Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when AC power has been restored following an AC
power outage.
6
66
674
Low Battery Restore Report Code
0 = No Report, 1-9, B-F (as described above).
Sent when a system low-battery condition is restored to
normal.
6
66
675 -6
66
692 NOT USED
6
66
693
Reports per Armed Period
0 = 10 max total alarm + alarm restores; 1 = Unlimited
Limits the number of alarm/alarm restore reports
message pairs per zone sent to the Central Station in an
armed period.
Download Information (
6
66
6
94-
6
66
6
97)
6
66
694
Download Phone No.
Enter up to 12 digits. 0-9 # + 11 for *; # + 12 for #; # +
13 for 2 second pause
Enter the phone number of the downloading computer.
Do not fill unused spaces. If fewer than 12 digits exit
field by pressing * (and press 95, if entering next field).
To clear entries press *94*.
6
66
695
Ring Detection Count for Downloading
0 = Disable station initiated download; 1-14 = number of
rings (1-9, #+10 for 10, #+11 for 11, #+12 for 12, #+13
for 13, #+14 for 14); 15 = answering machine defeat
6
66
696
Initialize Download ID and Subscriber
Account Number
This must be done before the first
download. Once initiated, do not re-enter
another subscriber account number
manually. This would void the *96
command.
6
66
697
Zeroes all Program Fields
Resets all data fields to factory default settings.
Exit Program Mode (
6
66
6
98 or
6
66
6
99)
6
66
698
Exit Programming Mode
Prevents re-entry by [Master Code] + [Code] key + [0]
6
66
699
Exit Programming Mode
Allows re-entry by [Master Code] + [Code] key + [0]

Other manuals for Honeywell ADEMCO 4110XM

Related product manuals