FIELD
TITLE and DATA ENTRIES EXPLANATION
*47
Phone System Select/Dialer
Attempts
Phone System Select:
If Central Station Receiver is not on satellite
link: 0 = Decadic Pulse Dial; 1 =
Multifrequency Tone Dial
If Central Station Receiver is on satellite
link: 2 = Decadic Pulse Dial;
3 = Multifrequency Tone Dial
Dialer Attempts: 1 – 10 (for 10, enter #+10)
Phone System Select: Select the type of telephone service.
Dialer Attempts: Enter the number of times the system should
attempt to dial the central station, 1 – 10 times (for 10, enter #+10).
*48
Report Format (Primary/Secondary)
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = CID* using 10-digit account number
6 = 4+2 ADEMCO EXPRESS
7 = CID* using 4-digit account number
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
10 = ROBOFON 8 (6-digit account number)
11 = ROBOFON Contact ID
Select report format for primary and secondary phone numbers.
* ADEMCO Contact ID format
Audio Beeps Format (Follow-Me): To enable the audio “beeps”
format (Follow-Me feature), refer to the System Features section
later in this manual, and the User Guide.
Special Contact ID Report Codes: The following three reports are
valid only when Contact ID format is enabled: 412-Successful
Download/Access (see field *53), 461-Wrong Code Entry (see field
*188), and 626-Time/Date Inaccurate (see field *53).
*49
Split/Dual Reporting
0 = disable (standard/backup report only).
1 - 5 (see table to right)
To Primary No. To Secondary No.
1 = alarms, restore, cancel others
2 = all except open/close, test open/close, test
3 = alarms, restore, cancel all
4 = all except open/close, test all
5 = all all
*50
Burglary Dialer Delay
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Provides delay of “BURGLARY ALARM” report to the central station,
which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible
alarm, auxiliary alarm), which are always sent as soon as they occur.
*51
Part. 3 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48.
*52
Part. 3 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48.
*53
SESCOA/Radionics Select/
CID Codes
SESCOA/Radionics:
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Contact ID Codes:
0 = disable both Time/Date Inaccurate and
Successful Download/Access reports
1 = enable Time/Date Inaccurate report
(code 626);
2 = enable Successful Download/Access
report (code 412)
3 = enable both Time/Date Inaccurate and
Successful Download/Access
SESCOA/Radionics:
Select SESCOA or Radionics format.
Select 0 for all other formats.
Contact ID (CID) Codes: If desired, enable the Time/Date
Inaccurate and/or Successful Download/Access report codes. These
reports are valid only when Contact ID reporting format is used.
*54
Dynamic Signaling Delay
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Intended for use with ECP Contact ID Output reporting via ACM.
This field lets you select the time the panel should wait for
acknowledgment from the first reporting destination (see 55) before
it attempts to send a message to the second destination. Delays can
be selected from 0 to 225 seconds, in 15-second increments. This
delay is per message. If ”0” is entered in this field, the control panel
will send redundant reports to both Primary Dialer and ECP output.
Installation Instructions