*66
Arm Away/Stay Report Code
0 = disable; 1-F = see description above 59
This option allows for independent programming of Away and Stay
reports for each partition.
NOTE: “OPEN” reports are not sent if the associated closing report
is not enabled.
*67
RF Low Battery Report Code
0 = disable; 1-F = see description above 59
Sent when a wireless transmitter low-battery condition exists.
*68
Cancel Report Code
0 = disable; 1-F = see description above 59
Sent upon disarming of the system after an alarm condition was
reported.
*69
Alarm Restores
Send restore code (if fault cleared):
0 = at siren timeout (if restored) or at
disarm (whether restored or not)
1 = dynamically as the fault clears
2 = only after a disarm
Alarm restore message will be sent upon condition selected.
*70
Alarm Restore Report Code
0 = disable; 1-F = see description above 59
Sent when an alarm zone is restored to its non-faulted condition or at
the times selected in field *69.
*71
Trouble Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a trouble in a zone is restored
*72
Bypass Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a zone that has been bypassed is unbypassed, either
manually or when the partition/system is disarmed.
*73
AC Mains Restore Report Code
0 = disable; 1-F = see description above 59
Sent when AC mains has been restored after an AC mains outage.
*74
Low Battery Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a system low-battery condition is restored to normal.
*75
RF Low Battery Restore Code
0 = disable; 1-F = see description above 59
Sent when a transmitter’s low battery condition is restored (i.e., new
battery installed).
*76
Test Restore Report Code
0 = disable; 1-F = see description above 59
Sent when the Test mode is exited.
Miscellaneous System Fields
FIELD
TITLE and DATA ENTRIES EXPLANATION
*77
Summer Time
Start/End Month
0 = Disabled 4 = April
1 = Jan # + 10 = Oct
2 = Feb # + 11 = Nov
3 = Mar # + 12 = Dec
Enter the start and end month for summer time, if applicable to the
region.
*78
Summer Time
Start/End Weekend
0 = disabled 4 = fourth
1 = first 5 = last
2 = second 6 = next to last
3 = third 7 = third to last
Enter the start and end weekend for summer time, if applicable to
the region.
*84
Auto-Stay Arm
0 = no
1 = partition 1 only
2 = partition 2 only
4 = partition 3 only
Add values for multiple partitions (e.g. for
partitions 1 and 2, enter 3).
If enabled, the system will automatically change AWAY or
MAXIMUM modes to STAY and INSTANT modes respectively if the
entry/exit door is not opened and closed within the exit delay time
after a user arms in AWAY mode from a wired keypad (non-RF
device). An Opening report followed by an Armed Stay report is sent
to the Central Station.
If the door is opened and closed within the exit delay period, the
system remains in AWAY or MAXIMUM mode.
Any RF device that arms the system AWAY overrides this feature
and the system remains armed in the AWAY mode.
NOTE: Must not be used if TeleCommand is used.
Does not apply if:
Final Contact Set exit option (field *88, option 3) is enabled.