*188
Keypad Sabotage Options
Entry 1: Keypad Lockout:
0 = disable; 1 = enable 15 minute lockout
Entry 2: Keypad Supervision and Tamper
Fault Detection: 0 = no, 1 = yes
Entry 1. If selected, will lockout the keypad for 15 minutes if 30
keystroke entries (6 attempts of code + command) are made without
a valid user code being detected. While the keypad is locked out, a
message "Code Sabotage" will be displayed on the keypads in the
partition that is locked out. A message will be transmitted to the
central station (461 Wrong Code Entry) if Contact ID format is
selected as reporting format in field *48 (if Contact ID format is not
being used, this event is not reported). The Wrong Code Entry is
always logged in the event log.
Entry 2. Enables or disables keypad supervision (ECP addresses 16-
23) in the control. If selected, keypads are supervised for connection
and tamper. These conditions cause a trouble when disarmed, alarm
when armed.
AUI Device and Keypad Programming Fields
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
FIELD
TITLE and DATA ENTRIES EXPLANATION
*189
AUI Device 1 and 2 Enable
(for Touch Screen Style Keypads)
0 = disabled
1 = partition 1
2 = partition 2
3 = common partition
NOTE: Use of AUI does not affect the number of
standard keypads supported.
The System supports up to two touch screen style keypads (e.g.,
Symphony Advanced User Interface, and 6270 Touch Screen Keypad).
Enter each AUI’s home partition.
AUI Compatibility Note: To ensure proper AUI device operation,
use AUI devices with the following rev levels: 6270 series use
version 1.0.9 or higher; 8132/8142 (Symphony) series use version
1.1.175 or higher.
Touch Screen (AUI) device 1: Must set AUI device address to 1
Touch Screen (AUI) device 2: Must set AUI device address to 2
*190
Keypad 2 Device Address 17
Entry 1 – Partition Assignment:
0 = keypad disabled 2 = partition 2
1 = partition 1 3 = partition 3
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E beeps and
chime beeps
Keypad 2
Entry 1: enter the partition in which the keypad is located
Entry 2: Enter the desired sound option for this keypad.
NOTE: Address 16 is reserved for keypad 1, which is factory set to
partition 1 with all sounds enabled.
*191
Keypad 3 Device Address 18
Keypad 3 See field *190 for entries and explanation.
*192
Keypad 4 Device Address 19
Keypad 4 See field *190 for entries and explanation.
*193
Keypad 5 Device Address 20
Keypad 5 See field *190 for entries and explanation.
*194
Keypad 6 Device Address 21
Keypad 6 See field *190 for entries and explanation.
*195
Keypad 7 Device Address 22
Keypad 7 See field *190 for entries and explanation.
*196
Keypad 8 Device Address 23
Keypad 8 See field *190 for entries and explanation.
*197
Exit Time Display Interval
0 = no display
1-5 = seconds between display refreshing
If enabled, keypads display the exit delay time remaining after arming
the system, with display updates at the interval selected (i.e. if the
exit delay is 30 seconds and “2” is selected in this field, the keypad
display refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than “1” may be necessary for some older keypads
to allow users time to enter key presses between display updates.
*198
Display Partition Number
0 = no; 1 = yes
If selected, the partition number is displayed in the upper-left corner
of the display. This is useful when using the GOTO partition function.
*199
ECP Device Fail Display
0 = 3-digit display (“1” + device address)
1 = 2-digit fixed-display as “91”
Select “0” if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads (6148, 6150, 6160, 6164). ECP faults for keypads and/or other
peripheral ECP devices will display “1” plus the device address (00-30)
of device causing the fault (e.g., faults on device 07 display as “107”).
Select “1” if using 2-digit Fixed-Word Display keypads (e.g., certain
6128RF series keypads). If selected, ECP faults for keypads and/or
peripheral devices will display as “91” on 2-digit displays, and “191”
on 3-digit or Alpha keypads.
Installation Instructions
4-12