5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone
(e.g., a 5804's four inputs require four programming zones).
LOOP 1
5808
ENROLL AS
"RF"
LOOP 1
5809
ENROLL AS
"RF"
5802MN2
ENROLL AS
"UR" OR "RF"
LOOP
1
5852 (GBD)
ENROLL AS
"RF"
(Green)
(Red)
(Yellow)
VISTA48A-001-V0
LOOP 1
(MOTION)
5890 / 5890PI
ENROLL AS
"RF" OR "RM"
5804BD
ENROLL AS
"BR"
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
SET
HOUSE
CODE
LOOP 3
LOOP 1
LOOP 2
5804
ENROLL AS "BR"
OFF
ON
5817
ENROLL AS
"RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5816
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5816MN
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5819S (WHS & BRS)
ENROLL AS
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5819
ENROLL AS
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5801
ENROLL AS
"UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 3
NOTE: For information on any
transmitter not shown, refer to the
instructions accompanying that
transmitter for details regarding loop
numbers, etc.
Compatible 5800 Series Transmitters Table
Model Product Input Type Description
5801
Wireless Panic
Transmitter
UR or RF
• Four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Panic, Arm, Disarm, etc.)
5802
Pendant (Personal
Emergency Transmitter)
BR Only
• Has single pushbutton.
• Usually programmed for response type of 24-Hr audible or 24-Hr
Silent (other zone responses are possible).
5802CP
Belt Clip (Personal
Emergency)
BR Only
Same as 5802.
5802MN
5802MN2
Miniature (Personal
Emergency Trans.)
UR or RF
Same as 5802.
5804
Wireless Key
Transmitter
BR Only
• Has four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Arm, Disarm, etc.)
5804BD
Bi-Directional
Wireless Key
BR Only
• House ID must be set.
• Requires 5800TM Transmitter Module or 5883 Transceiver.
• Can indicate system status via its 2 LEDs and built-in sounder.
• Has four pushbuttons, each with a unique input (loop) code.
• Operates the system similarly to wired keypads.
5806
5807
5808LST
Wireless
Photoelectric Smoke
Detectors
RF
One-piece smoke detectors with a built-in transmitter.
5809
Heat Detector RF
One-piece rate-of-rise heat detector with a built-in transmitter.
5816
5816MN
Door/Window
Transmitters
RF
Has two unique input (loop) codes: one for a wired closed circuit
contact loop; the other for its built-in reed switch (used with a
magnet).
8-3