Security Codes
The system supports up to 48 security codes, which can each be assigned one of 5 authority levels.
The authority level determines the functions each code can perform as follows:
Authority Levels
(authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be changed)
Level User No. Functions
Installer 01 perform all security functions except can disarm only if used to arm;
can enter program mode; can change System Master code; cannot assign
any other user codes (default = 4112)
System 02 only one system master code per system; can perform all security
Master functions, add/delete users in all partitions, change system master code,
view event log, set system clock, program keypad macro, program
scheduled events, activate output devices (triggers/relays) (default = 1234)
Partition P1 = 03 Same as Master, except add/delete users limited to
Master P2 = 25 assigned partition only, (these users can be assigned different authority
(default) P3 = 41 levels, if desired; any user can be assigned the partition master authority
level)
0-User 03-49 perform security functions (arm, disarm, etc.) only; cannot add/delete
users, view event log, set system clock or program scheduled events
1-Arm Only see “user” arm system only
2-Guest see “user” can disarm the system only if it was used to arm the system
3-Duress see “user” performs security functions, but also silently sends a duress message to the
central station; reports as duress code user number.
4-Partition see “user” See Partition Master paragraph above; used to assign
Master other user numbers as partition masters
Refer to the user guide for detailed procedures on adding/deleting security codes and changing user
attributes.
The following is a brief description of how to add user codes.
Adding a User Code: Master code + [8] + 2-digit user no. + user’s code
Deleting a User Code: Master code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
Attributes: Values
1 = Authority Level 0-4 (see Authority Level table above)
2 = Access Group 0-8 (0 = not assigned to a group)
3 = Active Partition(s) 1, 2, 3
for this user; Enter partitions consecutively if more than
one and press [#] to end the entries.
4 = RF Zone No. Assigns user number to button type zone for
arm/disarm (keyfob must be enrolled in system
first; see Wireless Key Templates section)
5 = Open/Close Paging 1 for yes, 0 for no
6 = Open/Close Report to 1 for yes (default = yes for all users), 0 for no
Monitoring Station
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming Mode
Exit Delay Entry Delay Perimeter Armed Interior Armed
AWAY Yes Yes Yes Yes
STAY Yes Yes Yes No
NIGHT-STAY Yes Yes Yes
only those zones
listed in Night-
Stay zone list
INSTANT Yes No Yes No
MAXIMUM Yes No Yes Yes
6-5