01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[] to continue
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to “A” prompt)
2 = zone type (go to “B” prompt)
3 = zone number (go to “C” prompt)
If you enter “0,” the following prompt appears:
Delete? Press 1 to delete this
0 = NO, 1 = YES output definition.
A
01 Zn List
1
Zone List
01-12 = zone list
[] to continue
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Zone lists 09-12 can be used in output definitions if not used
for paging or for exit zone definition.
Press [] to continue.
Enter the zone list event that will activate this output.
Enter Event 0 = restore; 1 = alarm;
Alarm 1 2 = fault; 3= trouble
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output.
Press [] to continue and skip to the “Output Action” prompt.
B
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used 06 = 24 Hr Silent 15 = Medical
01 = Ent/Exit #1 07 = 24 Hr Audible 16 = Fire w/verification
02 = Ent/Exit #2 08 = 24 Hr Aux 23 = No Alarm Response
03 = Perimeter 09 = Fire 24 = Silent Burglary
04 = Interior Follower 10 = Interior w/Delay 77 = Keyswitch
05 = Trouble Day/ 12 = Monitor Zone 81 = AAV Monitor Zone
Alarm Night 14 = Gas 82 = Blockschloss
90-93 = Configurable
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay 41 = **AC Mains Failure 67 = Siren Fail
21 = Arming–Away 42 = **System Batt Low 68 = Telecom Line Cut
22 = Disarming 43 = Comm. Failure 69 = Telecom Line Restore
31 = End of Exit Time 46 = Sys Batt Restore** 70 = AC Mains Restore**
32 = Start of Entry Time 52 = Kissoff 71 = System Startup/Clock Not
33 = Any Burglary Alarm 54 = Fire Zone Reset Set
36 = **At Siren Timeout*** 58 = Duress 72 = Clock Set
38 = Chime 60 = AAV 78 = Keyswitch Red LED
39 = Any Fire Alarm 66 = Function Key 79 = Keyswitch Green LED
40 = Bypassing 80 = Tamper Fault
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
Use *57 Menu Mode to assign the function key (function “07”).
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition 0 = any partition; 1 = partition 1;
Any partition 0 2 = partition 2; 3 = partition 3
Press [] to continue and skip to the “Output Action” prompt.
5-11