3. Remove the scan bracket assembly (refer to scan bracket assembly operation).
4. Remove the display assembly (refer to LCD Display & Touch Panel operation).
5. Using a T7 torx driver remove three screws that attach the main logic board to the magnesium frame.
Installation
1. Position the main logic board onto the magnesium frame.
2. Using a T7 torx driver install 4 screws and secure the main logic board to the magnesium frame with 2.5+/-0.2 inlbs of
torque.
3. Re-install the display assembly.
4. Re-install the Scan bracket assembly.
5. Re-install the core assembly into the top housing.
6. Re-install the bottom housing assembly.
OPERATION:
Magnesium Frame
Replacement of the magnesium frame will require a complete disassembly of the unit.
Tools Required
Description
Part Number
T10 Torx driver
T7 Torx driver
Phillips screwdriver with #0 tip