27
Wiring Electrical Door Lock
Wire door strikes and magnetic locks.
Wiring Door Strikes
Follow these steps to wire door strike to the Controller Board:
Use the following figure to locate the door strike terminals on the
controller and to wire the door strike lock according to the power
supply used.
Be sure to use the S4 suppressor kits as shown below. The 12VDC
OUT is limited to 500mA. In this case the controller may be powered
using PoE or external 12VDC.
The DR LCK SWITCHED GROUND (SW GND) door operation can be
set in the web user interface and host software as FAIL SAFE, or
FAIL SECURE.
If the door operation is set for FAIL SECURE a door strike that locks
without power can be connected
If the door operation is set for FAIL SAFE the door strike that
releases without power can be connected
Wiring an Access Control Door Strike
Note: S4 Suppressor kits are not evaluated by UL294 and CAN/
ULC60839-11-1.