55
³ 9 9 6 0 4 4
³ 9 9 6 0 4 2
Bar Code Calibration Procedure without Remote Display*
Unit Calibration (Pounds)
For Kilogram weight units see instructions on page 55.
Figure 49. Entering Bar Code Calibration Mode (Pounds)
Note: If a razz tone sounds, an error has occurred. Refer to Diagnostic Indicator Display; Error Codes
starting on page 40 for additional information.
Unit Calibration (Kilograms)
For Pound weight, units see instructions on page 54.
Figure 50. Entering Bar Code Calibration Mode (Kilograms)
Note: If a razz tone sounds, an error has occurred. Refer to Diagnostic Indicator Display; Error Codes
starting on page 40 for additional information.
* These procedures are for MS2420/MS2430 Scanner/Diva Scale models only.
Kilograms Calibration
Pounds Calibration