5–1
SECTION 5
System Operation
•••••••••••••••••••••••••••••••••••••••••••
Power Up/System Reset
SYSTEM STABILIZATION MODE: Upon power-up of the system, if the system was previously armed,
all the lights on the LED keypad(s) will turn ON momentarily or, in the case of an LCD display
installation, the keypad(s) will display “PLEASE STAND BY POWER UP DELAY”
HOWEVER, THE ZONES WILL NOT RESPOND TO ALARM CONDITIONS FOR APPROXIMATELY
2 MINUTES. The 2-minute interval is used to allow motion detectors (interior zones) to stabilize in
order to prevent false alarms. This 2-minute delay can be disabled by shorting the yellow and black
keypad wires (reduces the power-up reset time to approximately 5 seconds). Upon system power-up, if
the system was previously disarmed, the power-up reset time will be approximately 5 seconds. If total
system power is lost, upon power restoral the system will return to its previously armed state.
Keypads
The control panel supports the following keypads:
OMNI-LCD Alpha Keypad
OMNI-LCD-US Alpha Keypad
STAY
BYPASS
INSTANT
CODE
1
2
3
4
5
6
7
8
9
*
0
#
XK-7LC_kypd
XK7LC Alpha Keypad
ALARM
FIRE
INSTANT
BYPASS
TRBL
PAGE
STAY
SUPRVSN
CANCELED
CHIME
BAT
NOT READY
PHONE
TEST
TAMPER NO AC
OMNI-KP Fixed-Word Keypad
ALARM
FIRE
INSTANT
BYPASS
TRBL
PAGE
STAY
SUPRVSN
CANCELED
CHIME
BAT
NOT READY
PHONE
TEST
TAMPER NO AC
OMNI-KP-US Fixed-Word Keypad
XK108 LED Keypad
(Displays the state of up to 8
zones via LEDs)
NOTE: OMNI-LCD, OMNI-KP, and XK7LC keypads are not for sale in the USA.