OMNI624 Installation and Setup Guide
5–10
where:
MASTER USER User with authority level 1 or 2.
USER NO. The user that will be assigned access to other partitions.
1, 2, or 4 Select 1 or 2 to assign access to a partition to that user.
Select 4 to enable open/close paging report for that user.
To exit this mode, press [✱].
User code programming can ONLY be performed while the system is DISARMED.
User Deletion
User codes (02–32) can be deleted from any keypad. Once deleted, their values are null.
TO DELETE USERS:
[CODE] + MASTER CODE + USER NO. + [#]
where:
[CODE] [CODE] button on keypad.
MASTER CODE Master User code.
USER NO. Desired user number being deleted (02–32).
[#] [#] button.
Keypad Emergency Conditions
The system is capable of transmitting four keypad auxiliary conditions as follows:
CONDITION KEYSTROKES CS REPORT ENABLE
OPTIONS
(aud./silent; arm beeps; relays)
PANIC
# & ✱ (at the same
time)
Submode 2, Question
38, L1, L2
See Submode 1, Question 27,
L1, L2
Immediate and unabortable.
FIRE
7 & 9 (at the same
time)
Submode 2, Question
40, L1, L2
See Submode 1, Question 26,
L3, L4
AUXILIARY
1 & 3 (at the same
time)
Submode 2, Question
40, L3, L4
See Submode 1, Question 26,
L1, L2
DURESS
User code #31 and
32
Submode 2, Question
37, L1, L2
See Submode 1, Question 13,
L1
The keypads have additional keys dedicated for emergency conditions. These can be activated by
pressing both keys at the same time (see “Keypads” in this section).
Audible Panic, Fire, and Audible Auxiliary can be RESET BY ENTERING ANY VALID USER CODE.